FIXINS HOME SERVICES | B=R | C | 06/21/2022 | | STEINM | STEINM | | B=R | C | 255159 |
FIXINS HOME SERVICES | B=R | R | 06/06/2022 | still missing gable trim | STEINM | STEINM | | B=R | R | 254678 |
FIXINS HOME SERVICES | B=R | P | 04/18/2022 | Trim missing at prow | TROEGERR | TROEGERR | | B=R | P | 253365 |
FIXINS HOME SERVICES | BE | P | 04/13/2022 | Renewed for No Fee at 4/13/2022 12:15:45 PM | MORGANL | MORGANL | | BE | P | 253279 |
FIXINS HOME SERVICES | BE | P | 02/18/2021 | Renewed for No Fee at 2/18/2021 11:24:05 AM | CAMPBELLRK | CAMPBELLRK | | BE | P | 243058 |
HOMEOWNER | B= | R | 03/02/2020 | Additional Inspections Required: Floodplain Final Inspection is not Completed yet. Insulate/condition crawlspace Need plans on site to verify crawlspace beam/posts Secure steel columns in crawlspace to concrete pads Block off exterior door to future deck | TROEGERR | TROEGERR | | B= | R | 234506 |
UNKNOWN | BE | P | 02/13/2020 | Renewed for No Fee at 2/13/2020 10:48:06 AM | CAMPBELLRK | CAMPBELLRK | | BE | P | 234240 |
D & D CUSTOM HOME REMODELING | BE | P | 02/13/2020 | Renewed for No Fee at 2/13/2020 10:47:53 AM | CAMPBELLRK | CAMPBELLRK | | BE | P | 234239 |
D & D CUSTOM HOME REMODELING | BFR | C | 03/04/2019 | Corrections completed | TROEGERR | TROEGERR | | BFR | C | 224818 |
D & D CUSTOM HOME REMODELING | BSP | C | 03/01/2019 | RCVD ENG FOR FRAMING | CORCORANC | CORCORANC | | BSP | C | 224806 |
D & D CUSTOM HOME REMODELING | BSP | P | 11/15/2018 | 2 interior pads in crawlspace one is 2'X6' and one is 3'X3' | BRUNETTET | BRUNETTET | | BSP | P | 222463 |
FIXINS HOME SERVICES | B=R | P | 07/09/2018 | | TROEGERR | TROEGERR | | B=R | P | 218497 |
D & D CUSTOM HOME REMODELING | BIN | P | 06/25/2018 | Upstairs level only 2x6 rafters in small bedroom alcove addition have R-38? | TROEGERR | TROEGERR | | BIN | P | 218299 |
D & D CUSTOM HOME REMODELING | BFR | P | 06/20/2018 | upstairs ok to insulate | BRUNETTET | BRUNETTET | | BFR | P | 218217 |
D & D CUSTOM HOME REMODELING | BFR | R | 06/13/2018 | Add blocks in walls over 10', and at 4' from outside wall corners (shear blocking) Add studs to each side and at each end of posts under ridge beam Point loads under bearing points, carry down to foundation Add posts and pads in center of span of two LVL beams in crawl space Cannot access small addition to verify floor system Post at north end of 14" LVL is bearing on padded out section of foundation not original stem wall | TROEGERR | TROEGERR | | BFR | R | 218076 |
D & D CUSTOM HOME REMODELING | BGF | C | 05/30/2018 | | BRUNETTET | BRUNETTET | | BGF | C | 217727 |
FIXINS HOME SERVICES | BUL | C | 05/14/2018 | | BRUNETTET | BRUNETTET | | BUL | C | 217702 |
D & D CUSTOM HOME REMODELING | BSP | P | 05/14/2018 | met with contractor , he will be bringing a change order as soon as the engineer provides the letters | BRUNETTET | BRUNETTET | | BSP | P | 217397 |
D & D CUSTOM HOME REMODELING | BSH | C | 05/14/2018 | roof and wall sheathing ok | BRUNETTET | BRUNETTET | | BSH | C | 217396 |
FIXINS HOME SERVICES | BUL | R | 05/10/2018 | No sheathing inspection | HARRISJ | HARRISJ | | BUL | R | 217701 |
D & D CUSTOM HOME REMODELING | BFN | P | 02/14/2018 | Foundation walls Interior pads (2) to be poured after interior backfill | TROEGERR | TROEGERR | | BFN | P | 215565 |
D & D CUSTOM HOME REMODELING | BSP | C | 02/13/2018 | REC'D OPEN HOLE | GILLEYJ | GILLEYJ | | BSP | C | 215552 |
D & D CUSTOM HOME REMODELING | BFN | R | 02/13/2018 | Re-schedule with open hole letter | TROEGERR | TROEGERR | | BFN | R | 215539 |
D & D CUSTOM HOME REMODELING | BFT | C | 02/09/2018 | need wet stamp open hole | HARRISJ | HARRISJ | | BFT | C | 215469 |
HOMEOWNER | D= | C | 11/27/2017 | Direct access to County road. Built 1986. Inspected. Passed. Issued permit. Permit with application. | DINNOCENZOM | DINNOCENZOM | | D= | C | 213854 |
HIGH MOUNTAIN ELECTRIC INC | E= | C | 02/26/2020 | | WILSOND | WILSOND | | E= | C | 234423 |
HIGH MOUNTAIN ELECTRIC INC | E= | R | 11/05/2018 | Missing Lights, Smoke,Arc Rings, Counter Tops, dlw | WILSOND | WILSOND | | E= | R | 222176 |
HIGH MOUNTAIN ELECTRIC INC | ER | C | 05/29/2018 | | WILSOND | WILSOND | | ER | C | 217706 |
HIGH MOUNTAIN ELECTRIC INC | ER | P | 05/11/2018 | Recheck this rough. dlw | WILSOND | WILSOND | | ER | P | 217378 |
HIGH MOUNTAIN ELECTRIC INC | ER | T | 05/08/2018 | PAID (REC#924867) Not ready, Smokes missing,nail guards missing, wires to close to stud edges,wires not fastened at proper distance from box,bath fan not in place, wires stapled on edge,crawl not , other areas not done. Additions are 50 dollars per inspection. Call Me At 719 686 5409 AM 7:30 to 8:30, dlw | WILSOND | WILSOND | | ER | T | 217279 |
HIGH MOUNTAIN ELECTRIC INC | ER | R | 05/04/2018 | No one home. SCH | WILSOND | WILSOND | | ER | R | 217233 |
HOMEOWNER | H= | R | 03/02/2020 | Need gas shut-off for propane furnace in crawlspace Condition crawlspace | TROEGERR | TROEGERR | | H= | R | 234504 |
HOMEOWNER | HV | C | 03/02/2020 | | TROEGERR | TROEGERR | | HV | C | 234503 |
HOMEOWNER | HD | C | 06/13/2018 | Bathroom fan | TROEGERR | TROEGERR | | HD | C | 218077 |
HOMEOWNER | P= | C | 03/02/2020 | | TROEGERR | TROEGERR | | P= | C | 234505 |
HOMEOWNER | PTO | C | 05/18/2018 | | HARRISJ | HARRISJ | | PTO | C | 217531 |