Roof Truss P/SF: ?
PROJECT: ADDITION (
434
)
Submit Date
Approval Date
Type of Plan: Normal
Review Type: Parallel
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
County Map & Data
PPRBD Directions
Path 1 Location
Path 2 Location
Details
View
Log
Time Summary
Required Departments: 5
Log Entries: 14
Department
S
BoundColumn_2
Department
Construction
A
C
Construction
Floodplain
A
W
Floodplain
Roads & Bridges
A
R
Roads & Bridges
Triage
A
J
Triage
County Zoning
A
Z
County Zoning
Department
Splice
S
Date
Inspector
Reviewer
Comment
username
Department
tid
Open Plan Room
Original
/
1/25/2018
BRUNETTET
BRUNETTET
Path 2 Location = Open Plan Room by BRUNETTET
Open Plan Room
19304
Open Plan Room
Original
/
1/25/2018
BRUNETTET
BRUNETTET
Path 1 Location = Open Plan Room by BRUNETTET
Open Plan Room
19303
Construction
Original
A
1/25/2018
BRUNETTET
BRUNETTET
Construction
19302
Construction
Original
D
12/1/2017
SHARONOVAO
SHARONOVAO
PLEASE PROVIDE TWO COPIES OF THE FOLLOWING TO COMPLETE THE PLAN REVIEW PROCESS: A WRITTEN RESPONSE FOR EACH ITEM LISTED BELOW IS REQUIRED THAT SPECIFICALLY IDENTIFIES THE REVISION OR CORRECTION BEING MADE, AND 2 SETS OF BUBBLED OR HIGHLIGHTED REVISED DETAILS AND DRAWINGS ON NEWLY TO BE SUBMITTED PLAN SHEETS. (e-mail submittals will not be accepted)
IF THESE CORRECTION ITEMS ARE ON STAMPED PAGES THEY WILL REQUIRE THE DESIGN PROFESSIONAL OF THAT DISCIPLINE TO PROVIDE AND STAMP THESE NEW PAGES OF CORRECTIONS.
Please provide a letter addressing the fowling corrections:
Engineering is required for the following:
? 1. Provided prescriptive energy from is incomplete and not compliant with minimum values of 2009 IECC, provide res-check. (Include if house is on crawlspace, conditioned or vented)
? 2. Septic design is for 2 bedrooms, assessor’s office lists this house as a 2 bedroom house, the addition would add 3rd bedroom. Please address. Is the house going through remodel as well? If so, provide sq. ft. for the remodel and plans showing changes in the layout.
? 3. Elevations are incomplete. Please see application form and add additional required information.
? 4. Pages are not in order. S-1 is missing from one set. Please address.
? 5. Provide a complete submittal for the deck construction. Identify the sq. ft. added and/or redesigned. (Engineering is required.)
? 6. S-3(engineering is required) Please provide:
o Header size and framing for the new door in living room
o Roof over-framing details
o Roof framing plan does not have call outs for the details/sections
o Roof details/sections are missing from submittal
? 7. S-2(engineering is required) Please provide:
o Foundation grade
o Crawl space? Vented or conditioned?
o Attachment of steel post to LVB beam
NOTE: The remainder of the review will be completed as soon as the items are addressed.
IF YOU HAVE ANY QUESTIONS, PLEASE CALL ME AT (719) 686-5405 OR EMAIL ME, TO DISCUSS THE CONDITIONS OR SET UP AN APPOINTMENT TIME WHEN I CAN BE AVAILABLE TO MEET YOU AT THE COUNTER TO GO OVER THE PLANS.
Olya Sharonova sharonovao@co.teller.co.us Plans Examiner, Teller County
Construction
18969
Construction
Original
/
12/1/2017
SHARONOVAO
SHARONOVAO
Path 2 Location = Construction by SHARONOVAO
Construction
18968
Roads & Bridges
Original
A
11/27/2017
DINNOCENZOM
DINNOCENZOM
Existing Driveway. Built 1986.
Roads & Bridges
18921
Triage
Original
A
11/21/2017
CDD
CDD
REC'D UPDATED SITE PLAN
Triage
18912
County Zoning
Original
A
11/21/2017
CDD
CDD
County Zoning
18911
County Zoning
Original
D
11/20/2017
GILLEYJ
GILLEYJ
REC'D LEGIBLE ROOF FRAMING BUT STILL NEED SITE PLAN THAT SHOWS BACK PROPERTY LINE AND GARAGE AS FUTURE GARAGE
County Zoning
18900
Triage
Original
D
11/20/2017
GILLEYJ
GILLEYJ
REC'D ROOF FRAMING THAT IS LEGIBLE BUT NEW SITE PLAN STILL DOESN'T SHOW ALL PROPERTY LINES
Triage
18899
Triage
Original
D
11/13/2017
CORCORANC
CORCORANC
NEED ROOF FRAMING PAGE THAT IS LEGIBLE AND NEW SITE PLAN
Triage
18846
County Zoning
Original
D
11/13/2017
CORCORANC
CORCORANC
NEED BETTER SITE PLAN
County Zoning
18845
Floodplain
Original
A
11/13/2017
CORCORANC
CORCORANC
FEMA MAP # 08119C0170D
Floodplain
18844
Triage
Original
N
11/13/2017
CORCORANC
CORCORANC
septic on a48321 for 2 bedrooms
Triage