HOMEOWNER | B= | C | 09/04/2020 | INSPECTIONS AND FILE COMPLETE | CORCORANC | CORCORANC | | B= | C | 239101 |
RUSTIC MOUNTAIN BUILDERS, LLC | BGF | C | 09/01/2020 | Inspected with sheathing on 3/14/2018 | TROEGERR | TROEGERR | | BGF | C | 239013 |
HOMEOWNER | B= | P | 08/27/2020 | Additional Inspections Required: Floodplain Final Inspection is not Completed yet. | TROEGERR | TROEGERR | | B= | P | 238861 |
HOMEOWNER | BGF | C | 08/14/2020 | Inspected window flashing with sheathing | TROEGERR | TROEGERR | | BGF | C | 238497 |
HOMEOWNER | BSP | C | 08/14/2020 | Pre CO- need finals, need as built for septic, Garage on A49712 needs to be finaled out | CORCORANC | CORCORANC | | BSP | C | 238496 |
HOMEOWNER | B= | R | 08/14/2020 | Additional Inspections Required: Floodplain Final Inspection is not Completed yet. Need landing at exterior doors Need gripable handrail at stairs Need HFF Finish bathroom wall covering | TROEGERR | TROEGERR | | B= | R | 238492 |
RUSTIC MOUNTAIN BUILDERS, LLC | BSP | C | 09/24/2018 | REC'D ENG LTR - I JOIST RAFTER ATTACHMENT | GILLEYJ | GILLEYJ | | BSP | C | 220682 |
RUSTIC MOUNTAIN BUILDERS, LLC | BFR | C | 09/13/2018 | Corrections completed | TROEGERR | TROEGERR | | BFR | C | 220286 |
RUSTIC MOUNTAIN BUILDERS, LLC | BIN | C | 09/13/2018 | Insulation certs on site | TROEGERR | TROEGERR | | BIN | C | 220285 |
RUSTIC MOUNTAIN BUILDERS, LLC | BFR | P | 09/11/2018 | Add L 50 at gable wall corners Need letter from engineer regarding VPA substitution Double sill plate connection to foundation | TROEGERR | TROEGERR | | BFR | P | 220186 |
RUSTIC MOUNTAIN BUILDERS, LLC | BFR | P | 08/28/2018 | South wall shear wall framing Roof rafters, need engineer letter for 6" timber lock screws on bevel plates in lieu of VPA35 brackets at exterior walls, purlin and ridge beam | TROEGERR | TROEGERR | | BFR | P | 219804 |
RUSTIC MOUNTAIN BUILDERS, LLC | BPR | C | 04/25/2018 | 2 each | HARRISJ | HARRISJ | | BPR | C | 217010 |
BREASHEARS ROOFING | BUL | C | 03/16/2018 | | TROEGERR | TROEGERR | | BUL | C | 216255 |
RUSTIC MOUNTAIN BUILDERS, LLC | BSH | C | 03/14/2018 | Roof and walls | TROEGERR | TROEGERR | | BSH | C | 216208 |
RUSTIC MOUNTAIN BUILDERS, LLC | BFN | C | 11/06/2017 | | TROEGERR | TROEGERR | | BFN | C | 213389 |
RUSTIC MOUNTAIN BUILDERS, LLC | BFT | C | 10/24/2017 | | HARRISJ | HARRISJ | | BFT | C | 213061 |
RUSTIC MOUNTAIN BUILDERS, LLC | BFT | T | 10/23/2017 | PAID (REC#923029) No plans or permit on site, no open hole report Rebar installed incorrectly in corners, needs to be continuous | TROEGERR | TROEGERR | | BFT | T | 213018 |
AMPED UP ELECTRIC LLC | E= | C | 08/10/2020 | | HEDGESS | HEDGESS | | E= | C | 238357 |
BEAR NECESSITY ELECTRIC | ER | C | 08/23/2018 | | WILSOND | WILSOND | | ER | C | 219685 |
BEAR NECESSITY ELECTRIC | ER | R | 08/21/2018 | Need Bath Fan,Smokes not in correct locations. Nail Guards missing. dlw | WILSOND | WILSOND | | ER | R | 219587 |
HOMEOWNER | FP= | C | 09/04/2020 | | CORCORANC | CORCORANC | BDA | FP= | C | 239100 |
WESTERN FIREPLACE SUPPLY | HFF | C | 08/27/2020 | | TROEGERR | TROEGERR | | HFF | C | 238862 |
WOODLAND PLUMBING HEATING AND AIR CONDITIONING | H= | C | 08/14/2020 | Add transfer grill for mechanical room/laundry room makeup air | TROEGERR | TROEGERR | | H= | C | 238491 |
WOODLAND PLUMBING HEATING AND AIR CONDITIONING | HC | C | 09/30/2019 | | HARRISJ | HARRISJ | | HC | C | 230939 |
WOODLAND PLUMBING HEATING AND AIR CONDITIONING | HI | C | 06/14/2018 | | HARRISJ | HARRISJ | | HI | C | 218097 |
WESTERN FIREPLACE SUPPLY | HFV | C | 04/06/2018 | | TROEGERR | TROEGERR | | HFV | C | 216685 |
WOODLAND PLUMBING HEATING AND AIR CONDITIONING | P= | C | 08/14/2020 | | TROEGERR | TROEGERR | | P= | C | 238490 |
WOODLAND PLUMBING HEATING AND AIR CONDITIONING | PTO | C | 06/19/2018 | Washer box on exterior wall, needs to be protected from freezing | TROEGERR | TROEGERR | | PTO | C | 218202 |
WOODLAND PLUMBING HEATING AND AIR CONDITIONING | PTO | R | 06/14/2018 | Holes drilled through three consecutive studs No floor drain in mechanical room too many AAV's Water test not 10' of column | HARRISJ | HARRISJ | | PTO | R | 218096 |
WOODLAND PLUMBING HEATING AND AIR CONDITIONING | PB | C | 11/17/2017 | DWV and water lines under slab | TROEGERR | TROEGERR | | PB | C | 213744 |