191 STRONG DR, CRIPPLE CREEK, CO 80813
County Parcel #: 1005.223060270
Roof Truss P/SF: ?
PROJECT: SOLAR - ROOF MOUNT (PHASE 2) (
434
)
Submit Date
Approval Date
Type of Plan: Normal
Review Type: Parallel
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
County Map & Data
PPRBD Directions
Path 1 Location
Path 2 Location
Details
View
Log
Time Summary
Required Departments: 5
Log Entries: 7
Department
S
BoundColumn_2
Department
Construction
A
C
Construction
Electrical
D
E
Electrical
Floodplain
A
W
Floodplain
Triage
A
J
Triage
County Zoning
N
Z
County Zoning
Department
Splice
S
Date
Inspector
Reviewer
Comment
username
Department
tid
Electrical
Original
D
4/12/2024
STEINM
STEINM
DENIED A 2ND TIME PER J.B.
Electrical
38803
Construction
Original
A
4/12/2024
STEINM
STEINM
Construction
38802
Construction
Original
D
4/4/2024
STEINM
STEINM
• Need ENGINEERED ONE-LINE ELECTRIC DIAGRAM PLANS: show all major field installed electrical components and manufactures field specifications, wire identification and sizes, raceways and their sizes, grounding and existing equipment to be integrated with new system.
• Structural Analysis needs to meet the design criteria for Teller County. Wind load is 115 Vult (ultimate). Ground snow load is 57 psf. Roof live (snow) load is 40 psf.
Construction
38771
Electrical
Original
D
4/2/2024
BLOOMQUISTJ
BLOOMQUISTJ
NEED COLORADO ENGINEERING STAMP
Electrical
38753
Triage
Original
A
4/2/2024
BLACKBURNL
BLACKBURNL
RECEIVED 4/1/2024 EMAIL
PHASE 1 - see A63003/R16794 solar roof mount
PHASE 2 - is to add to existing PV system 18 additional modules as a 7.92 kW new system
HO Karina Moye: RLEEBEEME@AOL.COM
GC: PERMITTING_CO@FREEDOMSOLARPOWER.COM
Triage
38748
Floodplain
Original
A
4/2/2024
BLACKBURNL
BLACKBURNL
FEMA #08119C0355D
Floodplain
38747
County Zoning
Original
N
4/2/2024
BLACKBURNL
BLACKBURNL
Roof-mount solar.
Already PZ approved under Plan R16794/A63003
County Zoning
38746
© 2024 - PPRBD •