Log On
Clear
Permits
By Address
By Permit Number
Fee Calculator
Plans
By Address
List of Plans
Links
City PlanTrac
Colorado Springs Utilities
Home
Please wait...
Contact Support
Plan
565 FAIRVIEW DR, CRIPPLE CREEK, CO 80813
PERMIT#: A63170
County Parcel #: 1387.254070390
Roof Truss P/SF: ?
PROJECT: RESIDENCE / SEPTIC / DRIVEWAY (
101
)
Submit Date
Approval Date
Type of Plan: Normal
Review Type: Parallel
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
County Map & Data
PPRBD Directions
Path 1 Location
Path 2 Location
Details
View
Log
Time Summary
Required Departments: 6
Log Entries: 17
Department
S
BoundColumn_2
Department
Construction
D
C
Construction
Env. Health
A
H
Env. Health
Floodplain
A
W
Floodplain
Roads & Bridges
A
R
Roads & Bridges
Triage
A
J
Triage
County Zoning
A
Z
County Zoning
Department
Splice
S
Date
Inspector
Reviewer
Comment
username
Department
tid
Construction
Original
D
3/20/2024
STEINM
STEINM
• Need truss plans.
• The 2 x 8 deck joist cannot span 11’-0”. Either change to 10’-0” span or change to 2 x 10 at 16” o.c.
• Need framing details for interior bearing walls on 1st and 2nd floors.
• Need additional information for header sizing. A (2) 2 x 8 cannot span 6’-6” with 2 floors bearing or provide P.E. calculations. Also, need number of King and Jack (trimmers) studs for size of openings
Construction
38675
Env. Health
Original
A
5/16/2023
MAYA
MAYA
Approved.
Env. Health
36081
Env. Health
Original
/
5/16/2023
MAYA
MAYA
Path 1 Location = Env. Health by MAYA
Env. Health
36080
Roads & Bridges
Original
A
5/4/2023
KINCAIDB
KINCAIDB
direct access CM road
only 1 access allowed
pre-site completed
permit issued
Roads & Bridges
35948
Construction
Original
D
5/3/2023
WARCHOLR
WARCHOLR
CORRECTIONS NEEDED:
• Show Deck elevations on sheet A3, Missing north elevation view.
• Deck structural plan missing beam size, piers sizing for depth and diameter.
• Sheet S2 shows 2 post sizes? 4x4 and 6x6?
• Trusses for dormer and truss roof layout and design stamped by truss engineer needed.
• Missing all hardware connection callouts for all joists and trusses.
• 2nd floor framing plan is missing entire joist section, this needs to be on the drawings.
• Elevations don’t match framing details for openings for windows and doors.
• Floor plans don’t match elevations for openings.
• Stair framing details missing ledgers and connection hardware.
• This serves as a partial corrections list and a full re-review needs to be performed after these corrections are made.
Construction
35937
Env. Health
Original
/
4/28/2023
HOEKMANL
HOEKMANL
SENT TO EH 4/28/2023
Env. Health
35895
Roads & Bridges
Original
/
4/28/2023
HOEKMANL
HOEKMANL
SENT TO R&B 4/28/2023
Roads & Bridges
35894
Triage
Original
A
4/26/2023
HOEKMANL
HOEKMANL
Triage
35854
County Zoning
Original
A
4/26/2023
HOEKMANL
HOEKMANL
SITE PLAN APPROVED
County Zoning
35853
Triage
Original
D
4/11/2023
HOEKMANL
HOEKMANL
SUBS NEED TO BE LISTED ON APPLICATION
tires@intrawest.us
Triage
35749
Triage
Original
A
4/6/2023
HOEKMANL
HOEKMANL
SEPTIC APPLICATION RECEIVED.
Triage
35726
Triage
Original
D
4/4/2023
HOEKMANL
HOEKMANL
SOILS REPORT NEEDED FOR SEPTIC
SUBS NEED TO BE CLARIFIED ON APPLICATION
Triage
35703
Triage
Original
D
3/31/2023
HOEKMANL
HOEKMANL
SEPTIC APPLICATION DESIGN NEED TO BE PROVIDED.
SUBS NEED TO BE CLARIFIED ON APPLICATION
Triage
35685
Floodplain
Original
A
2/16/2023
HOEKMANL
HOEKMANL
FEMA MAP # 08119C0270D
Floodplain
35466
Triage
Original
D
2/16/2023
HOEKMANL
HOEKMANL
DRIVEWAY APPLICATION AND SEPTIC APPLICATION AND DESIGN NEED TO BE PROVIDED.
SUBS NEED TO BE CLARIFIED ON APPLICATION
APPLICATION NEED TO BE PROVIDED FOR GARAGE
Triage
35465
County Zoning
Original
D
2/16/2023
HOEKMANL
HOEKMANL
DOES NOT MEET REQUIREMENTS
County Zoning
35464
Triage
Original
D
2/8/2023
CARNEALD
CARNEALD
SUBMITTED ON 02/07/2023
tires@intrawest.us
Triage
35426
© 2024 - PPRBD •