Plan
642 IRWIN DR, FLORISSANT, CO 80816
PERMIT#: A52171
County Parcel #: 1385.221020020
Roof Truss P/SF: ?
PROJECT: RESIDENCE W/ GARAGE (
101
)
Submit Date
Approval Date
Type of Plan: Normal
Review Type: Parallel
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
County Map & Data
PPRBD Directions
Path 1 Location
Path 2 Location
Details
View
Log
Time Summary
Required Departments: 4
Log Entries: 8
Department
S
BoundColumn_2
Department
Construction
A
C
Construction
Floodplain
A
W
Floodplain
Triage
N
J
Triage
County Zoning
A
Z
County Zoning
Department
Splice
S
Date
Inspector
Reviewer
Comment
username
Department
tid
Open Plan Room
Original
/
12/4/2017
SHARONOVAO
SHARONOVAO
Path 2 Location = Open Plan Room by SHARONOVAO
Open Plan Room
18994
Open Plan Room
Original
/
12/4/2017
SHARONOVAO
SHARONOVAO
Path 1 Location = Open Plan Room by SHARONOVAO
Open Plan Room
18993
Construction
Original
A
12/4/2017
SHARONOVAO
SHARONOVAO
Construction
18992
Construction
Original
D
11/20/2017
SHARONOVAO
SHARONOVAO
PLAN REVIEW CORRECTIONS
PERMIT #: 13545
ADDRESS: 642 IRWIN DR.
PROJECT NAME: WAMPOLE
DATE OF REVIEW: 11/20/2017
PLANS EXAMINER: Olya Sharonova sharonovao@co.teller.co.us
SCOPE OF WORK: RESIDENCE W/GARAGE
STATUS: THE FOLLOWING CORRECTIONS ARE REQUESTED
PLEASE PROVIDE TWO COPIES OF THE FOLLOWING TO COMPLETE THE PLAN REVIEW PROCESS: A WRITTEN RESPONSE FOR EACH ITEM LISTED BELOW IS REQUIRED THAT SPECIFICALLY IDENTIFIES THE REVISION OR CORRECTION BEING MADE, AND 2 SETS OF BUBBLED OR HIGHLIGHTED REVISED DETAILS AND DRAWINGS ON NEWLY TO BE SUBMITTED PLAN SHEETS. (e-mail submittals will not be accepted)
IF THESE CORRECTION ITEMS ARE ON STAMPED PAGES THEY WILL REQUIRE THE DESIGN PROFESSIONAL OF THAT DISCIPLINE TO PROVIDE AND STAMP THESE NEW PAGES OF CORRECTIONS.
Please provide a letter addressing the fowling corrections:
? 1. Submitted energy form does not match plans. Please provide an energy compliance method for the project meeting minimum requirements of 2009 IECC.
? 2. Provide sq. ft. for the storage above the garage.
? 2. Engineering required:
o 5A-5B – identify all attachments for all rafters: (to walls, to beams, include bay window area.) 5B- some rafters do not show support below, please show all supporting walls/beams and connections to them.
o 5A – provide mechanical connections for 6”x8” glulams. Please elaborate on the note: “no penetrations permitted.”
NOTE: The remainder of the review will be completed as soon as the items are addressed.
IF YOU HAVE ANY QUESTIONS, PLEASE CALL ME AT (719) 686-5405 OR EMAIL ME, TO DISCUSS THE CONDITIONS OR SET UP AN APPOINTMENT TIME WHEN I CAN BE AVAILABLE TO MEET YOU AT THE COUNTER TO GO OVER THE PLANS.
Olya Sharonova
Plans Examiner, Teller County
Construction
18894
Construction
Original
/
11/20/2017
SHARONOVAO
SHARONOVAO
Path 2 Location = Construction by SHARONOVAO
Construction
18893
Floodplain
Original
A
11/9/2017
GILLEYJ
GILLEYJ
FEMA MAP# 08119C0235D
Floodplain
18803
Zoning/Planning
Original
A
11/8/2017
GILLEYJ
GILLEYJ
Zoning/Planning
18802
Triage
Original
N
11/8/2017
GILLEYJ
GILLEYJ
DRIVEWAY HAS BEEN FINALED ON PERMIT A51015 SEPTIC HAS BEEN FINALED ON PERMIT A51786 FOR 3 BEDROOM
Triage
18801