Log On
Clear
Permits
By Address
By Permit Number
Fee Calculator
Plans
By Address
List of Plans
Links
City PlanTrac
Colorado Springs Utilities
Home
Please wait...
Contact Support
Plan
982 COUNTY ROAD 89 , CRIPPLE CREEK, CO 80813
PERMIT#: A51877
County Parcel #: 10104.58020030
Roof Truss P/SF: ?
PROJECT: PRE-FAB SHED (
434
)
Submit Date
Approval Date
Type of Plan: Normal
Review Type: Parallel
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
County Map & Data
PPRBD Directions
Path 1 Location
Path 2 Location
Details
View
Log
Time Summary
Required Departments: 4
Log Entries: 9
Department
S
BoundColumn_2
Department
Construction
A
C
Construction
Floodplain
A
W
Floodplain
Triage
N
J
Triage
County Zoning
A
Z
County Zoning
Department
Splice
S
Date
Inspector
Reviewer
Comment
username
Department
tid
Open File Room
Original
/
10/6/2017
SHARONOVAO
SHARONOVAO
Path 2 Location = Open File Room by SHARONOVAO
Open File Room
18335
Open File Room
Original
/
10/6/2017
SHARONOVAO
SHARONOVAO
Path 1 Location = Open File Room by SHARONOVAO
Open File Room
18334
Construction
Original
A
10/6/2017
SHARONOVAO
SHARONOVAO
Construction
18333
Triage
Original
N
10/6/2017
SHARONOVAO
SHARONOVAO
Triage
18332
Triage
Original
/
10/4/2017
KROCHTAC
KROCHTAC
CORRECTIONS RECEIVED
Triage
18271
Construction
Original
/
9/26/2017
SHARONOVAO
SHARONOVAO
Path 2 Location = Construction by SHARONOVAO
Construction
18189
Construction
Original
D
9/26/2017
SHARONOVAO
SHARONOVAO
PLAN REVIEW CORRECTIONS
PERMIT #: 13446
ADDRESS: 982 COUNTY ROAD 89
PROJECT NAME: WESTWICK
DATE OF REVIEW: 09/26/2017
PLANS EXAMINER: Olya Sharonova sharonovao@co.teller.co.us
SCOPE OF WORK: PRE-FEB SHED
STATUS: THE FOLLOWING CORRECTIONS ARE REQUESTED
PLEASE PROVIDE TWO COPIES OF THE FOLLOWING TO COMPLETE THE PLAN REVIEW PROCESS: A WRITTEN RESPONSE FOR EACH ITEM LISTED BELOW IS REQUIRED THAT SPECIFICALLY IDENTIFIES THE REVISION OR CORRECTION BEING MADE, AND 2 SETS OF BUBBLED OR HIGHLIGHTED REVISED DETAILS AND DRAWINGS ON NEWLY TO BE SUBMITTED PLAN SHEETS. (e-mail submittals will not be accepted)
IF THESE CORRECTION ITEMS ARE ON STAMPED PAGES THEY WILL REQUIRE THE DESIGN PROFESSIONAL OF THAT DISCIPLINE TO PROVIDE AND STAMP THESE NEW PAGES OF CORRECTIONS.
Please provide a letter addressing the fowling corrections:
? 1. Submitted plans under 2009 IBC Teller County is under 2015 IBC/IRC, engineer to provide a letter stating the current plans meet or exceed 2015 requirements.
? 2. Engineer to address the total load on the roof of this structure: (life load +snow load +dead load)?
? 3. Please select all of the items that apply to the actual building to be installed. (S-3 and S-5) submitted plans have different options.
? 4. Identify the tie down system to be used from page S-2, and submit an actual, to be used tie information for the review to confirm compliance.
? 5. What is the use of the loft? The psf is only 5.
? 6. Please resubmit two sets of plans.
NOTE: The remainder of the review will be completed as soon as the items are addressed.
IF YOU HAVE ANY QUESTIONS, PLEASE CALL ME AT (719) 686-5405 OR EMAIL ME, TO DISCUSS THE CONDITIONS OR SET UP AN APPOINTMENT TIME WHEN I CAN BE AVAILABLE TO MEET YOU AT THE COUNTER TO GO OVER THE PLANS.
Olya Sharonova
Plans Examiner, Teller County
Construction
18188
Floodplain
Original
A
9/19/2017
KROCHTAC
KROCHTAC
FEMA MAP # 08119C0355D
Floodplain
18078
Zoning/Planning
Original
A
9/19/2017
KROCHTAC
KROCHTAC
Zoning/Planning
18077