Open Plan Room | Original | / | 7/20/2016 | SHARONOVAO | SHARONOVAO | Path 2 Location = Open Plan Room by SHARONOVAO | | Open Plan Room | 14262 | Open Plan Room | Original | / | 7/20/2016 | SHARONOVAO | SHARONOVAO | Path 1 Location = Open Plan Room by SHARONOVAO | | Open Plan Room | 14261 | Construction | Original | A | 7/20/2016 | SHARONOVAO | SHARONOVAO | | | Construction | 14260 | Construction | Original | / | 6/22/2016 | SHARONOVAO | SHARONOVAO | Path 2 Location = Construction by SHARONOVAO | | Construction | 13976 | Construction | Original | / | 6/22/2016 | SHARONOVAO | SHARONOVAO | Path 1 Location = Construction by SHARONOVAO | | Construction | 13975 | Construction | Original | D | 6/22/2016 | SHARONOVAO | SHARONOVAO | PLAN REVIEW CORRECTIONS NOTICE PERMIT #: 12785 ADDRESS: 270 COUNTY ROAD 51 PROJECT NAME: ELLSWORTH DATE OF REVIEW: 06/22/2016 PLANS EXAMINER: Olya Sharonova sharonovao@co.teller.co.us SCOPE OF WORK: HORSE BARN WITH HABITABLE AREA STATUS: THE FOLLOWING CORRECTIONS ARE REQUESTED
PLEASE PROVIDE TWO COPIES OF THE FOLLOWING TO COMPLETE THE PLAN REVIEW PROCESS: A WRITTEN RESPONSE FOR EACH ITEM LISTED BELOW IS REQUIRED THAT SPECIFICALLY IDENTIFIES THE REVISION OR CORRECTION BEING MADE, AND 2 SETS OF BUBBLED OR HIGHLIGHTED REVISED DETAILS AND DRAWINGS ON NEWLY TO BE SUBMITTED PLAN SHEETS. (e-mail submittals will not be accepted) IF THESE CORRECTION ITEMS ARE ON STAMPED PAGES THEY WILL REQUIRE THE DESIGN PROFESSIONAL OF THAT DISCIPLINE TO PROVIDE AND STAMP THESE NEW PAGES OF CORRECTIONS. Please provide a letter addressing the fowling corrections: ? 1. Steel barn plans are not printed to scale, please re-print plans to scale. (Too small can’t read and review.) ? 2. Barn elevations do not match floor plan, please address. ? 3. Please provide floor plan on minimum of 11x17 size and drawn to a conventional scale. ? 4. Provide details for interior wall framing and their attachment to the steel building. ? 5. Plans show some areas in the barn, which considered a habitable space per 2009 IRC. Please identify the minimum required insulation values per 2009 IECC or provide an energy compliance method such as res-check. ? 6. All habitable areas shall comply with 2009 IRC, sec. R303 light, ventilation, and heating, glazing openings. ? 7. Bathroom ventilation shall comply with R303.3.
NOTE: The remainder of the review will be completed as soon as the items are addressed.
IF YOU HAVE ANY QUESTIONS, PLEASE CALL ME AT (719) 686-5405 OR EMAIL ME, TO DISCUSS THE CONDITIONS OR SET UP AN APPOINTMENT TIME WHEN I CAN BE AVAILABLE TO MEET YOU AT THE COUNTER TO GO OVER THE PLANS.
Olya Sharonova Plans Examiner, Teller County | | Construction | 13974 | Env. Health | Original | / | 6/17/2016 | SMITHK | SMITHK | Path 1 Location = Env. Health by SMITHK | | Env. Health | 13885 | Env. Health | Original | A | 6/17/2016 | SMITHK | SMITHK | 6-17-16 Owner's plans are to connect facilities in the barn, a "non-habitable space," to the future septic system of their future home. (Permit # A49468) Barn will have a laundry area, shower, and toilet. This does not effect the size of the septic system as bedrooms are not added. Plans include proper schedule 40 pipe to slope down to the septic tank with proper cleanouts. | | Env. Health | 13884 | Triage | Original | N | 6/15/2016 | CORCORANC | CORCORANC | SOILS IS FROM SUBMITTAL OF HOUSE ON A49468 | | Triage | 13854 | Triage | Original | N | 6/15/2016 | CORCORANC | CORCORANC | | | Triage | 13853 | Floodplain | Original | A | 6/15/2016 | CORCORANC | CORCORANC | FEMA MAP # 08119C0185D | | Floodplain | 13852 | Zoning/Planning | Original | A | 6/15/2016 | CORCORANC | CORCORANC | | | Zoning/Planning | 13851 |
|
| |
|