GOODWIN KNIGHT LLC | B= | P | 08/29/2023 | Additional Inspections Required: Floodplain Final Inspection is not Completed yet. Bath House Landings installed, will require concrete flat work for walkways Ramp to be installed with Pavilion building | TROEGERR | TROEGERR | | B= | P | 266082 |
GOODWIN KNIGHT LLC | B= | P | 06/05/2023 | Additional Inspections Required: Floodplain Final Inspection is not Completed yet. Entry ramps, grab bars at ADA bathrooms, final grading -- Schedule a new Building Final when above items are complete. | TROEGERR | TROEGERR | | B= | P | 263917 |
GOODWIN KNIGHT LLC | BIN | C | 04/26/2023 | walls and under-floor insulation approved. check blow-in attic insulation after drywall/at final | STEVENSONR | STEVENSONR | | BIN | C | 262910 |
GOODWIN KNIGHT LLC | BFR | C | 04/21/2023 | All corrections made. | STEVENSONR | STEVENSONR | | BFR | C | 262797 |
GOODWIN KNIGHT LLC | BGF | C | 04/12/2023 | | STEINM | STEINM | | BGF | C | 262602 |
POMPEYA CONSTRUCTION INC. | BFR | R | 04/12/2023 | framing corrections not made. need electric rough prior to frame. add window flashing approved. | STEINM | STEINM | | BFR | R | 262588 |
POMPEYA CONSTRUCTION INC. | BFR | R | 03/23/2023 | need attic access. lateral bracing for truss B is installed in the wrong location. all windows require 2 king studs, missing on north end. need 16 gauge strapping where top plates do not overlap 24 inches, several places. missing blocking for ADA bathrooms. steel posts to pad need (2) 1/2" expansion bolts per and steel post top steel beam need (4) 3/4 inch bolts per detail 1/S2. treated plate to steel beam needs to attached per detail 2/S2. ramset nails are not at 16 inch o.c. and most did not penetrate steel beam. | STEINM | STEINM | | BFR | R | 262077 |
GOODWIN KNIGHT LLC | BSP | C | 02/22/2023 | CHANGE ORDER #1- PLUMBING AND ELECTRICAL CHANGES | WARCHOLR | WARCHOLR | | BSP | C | 261480 |
MDGREEN, LLC, DBA RED ROCK ROOFING | BUL | C | 02/07/2023 | Sufficient I&W | STEVENSONR | STEVENSONR | | BUL | C | 261204 |
POMPEYA CONSTRUCTION INC. | BSH | C | 01/30/2023 | Needs attic access. Need porta potty | BLOOMQUISTJ | BLOOMQUISTJ | | BSH | C | 261009 |
GOODWIN KNIGHT LLC | BSH | T | 01/06/2023 | PAID (REC#943784) Items that need to be addressed: Re Inspection Fee missing blocking 4ft from corners on inside wall & when section of wall is over 20 ft long center of that span there needs to be a section of 4ft blocking. Items that are correct: All wall sheathing was nailed off every 6" on corners, seams, & around window & door openings, & nailed off every 12" in the field. | GARNETTN | GARNETTN | | BSH | T | 260595 |
GOODWIN KNIGHT LLC | BSH | T | 12/28/2022 | PAID (REC#943741) Items that need to be addressed: Re Inspection Fee wall sheathing needs to be nailed off every 6" on corners, seams, & around doors & windows & every 12" in the field. Items that are correct: Roof sheathing nailed off every 6" on seams & every 12" in the field. | GARNETTN | GARNETTN | | BSH | T | 260387 |
ALPINE CONCRETE CONSTRUCTION I | BFN | C | 11/09/2022 | 2 rows #4 bar horizontal continuous top & bottom with 36" overlaps, verticals are @ 48" OC, Uffer ground is in the back corner of foundation wall. | GARNETT | GARNETT | | BFN | C | 259197 |
ALPINE CONCRETE CONSTRUCTION I | BFT | C | 11/04/2022 | Entire footing is 16" Wide X 8" deep with #4 bar continuous through out foot with 24" overlaps, Uffer ground is in back corner, there are four 28" X 28" pads with #4 bar as grids with four bars going either way. | GARNETT | GARNETT | | BFT | C | 259058 |
J2D ELECTRIC, INC | E= | C | 06/05/2023 | Bath House, dlw | WILSOND | WILSOND | | E= | C | 263904 |
J2D ELECTRIC, INC | E= | R | 06/02/2023 | Not ready | BLOOMQUISTJ | BLOOMQUISTJ | | E= | R | 263846 |
J2D ELECTRIC, INC | ES | C | 05/30/2023 | Commercial Service: | CDD | CDD | | ES | C | 263694 |
J2D ELECTRIC, INC | ES | T | 05/25/2023 | PAID (REC#944826) Conduit seals missing, Meyers hubs missing, dlw | WILSOND | WILSOND | | ES | T | 263663 |
J2D ELECTRIC, INC | EUG | C | 05/23/2023 | | BLOOMQUISTJ | BLOOMQUISTJ | | EUG | C | 263590 |
J2D ELECTRIC, INC | ER | C | 04/19/2023 | | BLOOMQUISTJ | BLOOMQUISTJ | | ER | C | 262735 |
J2D ELECTRIC, INC | ER | R | 04/17/2023 | Need switch,light and receptacle in attic . Dampers are serviceable equipment. 210.70 C | BLOOMQUISTJ | BLOOMQUISTJ | | ER | R | 262675 |
J2D ELECTRIC, INC | ER | P | 03/16/2023 | No Access to Crawl. dlw | WILSOND | WILSOND | | ER | P | 261957 |
PIERCE AIR & HEATING INC | H= | C | 06/02/2023 | Condensing units set, fan coils installed Complete bathroom exhaust fans Terminate condensate lines within 6" of ground Seal refrigerant lines at exterior wall | TROEGERR | TROEGERR | | H= | C | 263853 |
PIERCE AIR & HEATING INC | HRR | C | 03/20/2023 | approved for bath exhaust and 550 cfm with 12 inch duct. check condensate lines in crawl space at final. approved for mini split condenser lines. | STEINM | STEINM | | HRR | C | 261993 |
TEAM PLUMBING INC. | P= | C | 06/02/2023 | Fixtures set, Need grab bars at accessible restrooms | TROEGERR | TROEGERR | | P= | C | 263854 |
TEAM PLUMBING INC. | PTO | C | 03/02/2023 | approved for bath house | STEINM | STEINM | | PTO | C | 261643 |
TEAM PLUMBING INC. | PB | C | 03/02/2023 | not required | STEINM | STEINM | | PB | C | 261642 |