BEOWULF CONSTRUCTION & ENGR. I | B= | C | 10/08/2012 | CDSD Building review is complete. | MORGANL | MORGANL | | B= | C | 179963 |
BEOWULF CONSTRUCTION & ENGR. I | B= | P | 10/04/2012 | Additional Inspections Required: Certificate of Occupancy is pending review by CDSD staff. Floodplain Final Inspection is not Completed yet, Mechanical Final Inspection is not Completed yet, Driveway Final Inspection is not Completed yet. | HARRISJ | HARRISJ | | B= | P | 179886 |
BEOWULF CONSTRUCTION & ENGR. I | BIN | C | 09/06/2012 | Recd insulation cert. | LANDSITTELM | LANDSITTELM | | BIN | C | 179110 |
BEOWULF CONSTRUCTION & ENGR. I | BIN | P | 07/05/2012 | NEED CERT SHEET | LANDSITTELM | LANDSITTELM | | BIN | P | 177903 |
BEOWULF CONSTRUCTION & ENGR. I | BFR | C | 07/05/2012 | NEED TEMPERED GLASS AT UPSTAIRS WINDOW SEAT, CHECK AT FINAL | LANDSITTELM | LANDSITTELM | | BFR | C | 177902 |
BEOWULF CONSTRUCTION & ENGR. I | BFR | R | 06/26/2012 | Several point loads missing, truss laterals missing on A & C trusses, H2.5 mechanical connections do not meet uplift requirements of truss engineer, windows cut into gables, firestop/draftstop is not up to code in many areas, discussed the 6X6's on the decks too close to the concrete, requires a 1" separation, weep screed too close to the ground and a change order is required for master bedroom fireplace not being installed, gable windows, and tub not being installed. I recieved an engineering letter for several framing items (In file folder) and asked Josh to keep one on site and one for me to bring back for our files. I also allowed them to insulate and asked they keep it open for the inspections listed above, Josh said he would.--akc | CHAMBERLINA | CHAMBERLINA | | BFR | R | 177788 |
RAWSON ROOFING LLC | BUL | C | 06/18/2012 | | LANDSITTELM | LANDSITTELM | | BUL | C | 177641 |
BEOWULF CONSTRUCTION & ENGR. I | BFR | P | 06/18/2012 | NEED APPROVAL FOR MEANS OF H 2.5 CLIPS INSTALLED ALSO POST TO BASE FRONT PORCH OK TO COVER. This was corrected, I verified the H2.5's installed correctly.--akc | LANDSITTELM | LANDSITTELM | | BFR | P | 177640 |
BEOWULF CONSTRUCTION & ENGR. I | BFR | P | 06/15/2012 | partial covered porch, Josh will call in the am lags not 16" OC per eng. Mark stated that this has been corrected. | HARRISJ | HARRISJ | | BFR | P | 177634 |
BEOWULF CONSTRUCTION & ENGR. I | BGF | C | 06/14/2012 | Window flashing corrected. | HARRISJ | HARRISJ | | BGF | C | 177583 |
BEOWULF CONSTRUCTION & ENGR. I | BGF | R | 06/13/2012 | manufacture specs removed from all windows could not locate them project manager not on job site | HARRISJ | HARRISJ | | BGF | R | 177573 |
BEOWULF CONSTRUCTION & ENGR. I | BSH | C | 05/22/2012 | | LANDSITTELM | LANDSITTELM | | BSH | C | 177191 |
BEOWULF CONSTRUCTION & ENGR. I | BSP | C | 05/15/2012 | 7 deck piers RECD ENG FOR TYPICAL E SECTION PIER | LANDSITTELM | LANDSITTELM | | BSP | C | 177045 |
BEOWULF CONSTRUCTION & ENGR. I | BFD | C | 04/23/2012 | needs daylighted | HARRISJ | HARRISJ | | BFD | C | 176628 |
BEOWULF CONSTRUCTION & ENGR. I | BFN | C | 04/16/2012 | | LANDSITTELM | LANDSITTELM | | BFN | C | 176475 |
BEOWULF CONSTRUCTION & ENGR. I | BFT | C | 04/10/2012 | rec'd eng change to allow retaining wall to go 3' max and ok to slope retaining out of the ground | HARRISJ | HARRISJ | | BFT | C | 176408 |
WOODS EXCAVATION, INC. | D= | C | 10/05/2012 | | HARRISJ | HARRISJ | | D= | C | 179903 |
WOODS EXCAVATION, INC. | DE | P | 10/04/2012 | Renewed at 10/4/2012 9:46:10 AM | SHARONOVAO | SHARONOVAO | | DE | P | 179876 |
ELK CREEK ELECTRICAL, LLC | E= | C | 10/03/2012 | Check GD unit works at Building FINAL. dlw | WILSOND | WILSOND | | E= | C | 179868 |
ELK CREEK ELECTRICAL, LLC | E= | T | 10/01/2012 | PAID (REC#906506) Requires dedicated circuit to furnace, this means no other outlets such as service outlet. dlw per 422.12 | WILSOND | WILSOND | | E= | T | 179787 |
ELK CREEK ELECTRICAL, LLC | E= | T | 09/26/2012 | PAID (REC#906467) GFI missing for furnace area. light by man door does not work. missing second kitchen circuit. lower level outside outlets wired through two GFI recpts. dlw | WILSOND | WILSOND | | E= | T | 179668 |
ELK CREEK ELECTRICAL, LLC | E= | R | 09/26/2012 | Can find only one kitchen counter circuit. outlet by furnace must be GFI protected. lower level outside outlets appear to be wired through upper GFI by man door in garage to GFI downstairs. light by garage man door does not work. dlw | WILSOND | WILSOND | | E= | R | 179661 |
ELK CREEK ELECTRICAL, LLC | ES | C | 07/12/2012 | | WILSOND | WILSOND | | ES | C | 178020 |
ELK CREEK ELECTRICAL, LLC | ES | R | 07/11/2012 | Not ready. dlw | WILSOND | WILSOND | | ES | R | 177992 |
ELK CREEK ELECTRICAL, LLC | EUG | C | 07/11/2012 | | WILSOND | WILSOND | | EUG | C | 177991 |
ELK CREEK ELECTRICAL, LLC | EUG | T | 07/09/2012 | PAID (REC#905535) Trench shallow in two places. dlw | WILSOND | WILSOND | | EUG | T | 177949 |
ELK CREEK ELECTRICAL, LLC | ER | C | 06/26/2012 | Electrical rough now complete except for service to panel in garage. | CHAMBERLINA | CHAMBERLINA | | ER | C | 177787 |
ELK CREEK ELECTRICAL, LLC | ER | T | 06/21/2012 | PAID (REC#905406) Wiring was incomplete to the gutter receptacles, the wiring for the fireplace is incorrect.--akc | CHAMBERLINA | CHAMBERLINA | | ER | T | 177717 |
ELK CREEK ELECTRICAL, LLC | ER | P | 06/15/2012 | For two can lights at front entry. dlw | WILSOND | WILSOND | | ER | P | 177625 |
ELK CREEK ELECTRICAL, LLC | EST | C | 04/10/2012 | Although this is ok for temp it is not in compliance with IREA requirements for permanent service. dlw Temp service is not included in permit fee, it requires a payment of 50.00. dlw | WILSOND | WILSOND | | EST | C | 176393 |
ELK CREEK ELECTRICAL, LLC | FP= | C | 10/08/2012 | | MORGANL | MORGANL | | FP= | C | 179962 |
WESTERN FIREPLACE SUPPLY | HFF | C | 10/04/2012 | | HARRISJ | HARRISJ | | HFF | C | 179888 |
BROWN'S HEATING & COOLING | H= | C | 10/04/2012 | | HARRISJ | HARRISJ | | H= | C | 179887 |
WESTERN FIREPLACE SUPPLY | HV | C | 06/26/2012 | This inspection for the fire separation box, penetration, duct work and installation of f.p. The f.p. contractor has cut whopping holes in the firestop/draftstop that soemone has to close up. | CHAMBERLINA | CHAMBERLINA | | HV | C | 177786 |
BROWN'S HEATING & COOLING | HRR | C | 06/26/2012 | Bath exhaust ok, furnace venting complete, duct work ok, and supplies and returns are in place. | CHAMBERLINA | CHAMBERLINA | | HRR | C | 177785 |
PEAK PLUMBING & HEATING, INC. | HC | C | 06/13/2012 | RELEASE METER | HARRISJ | HARRISJ | | HC | C | 177571 |
PEAK PLUMBING & HEATING, INC. | HI | C | 06/13/2012 | | HARRISJ | HARRISJ | | HI | C | 177570 |
WOODS EXCAVATION, INC. | OS= | C | 04/30/2012 | Engineer approval letter received from contractor at final inspection. | DAHLK | DAHLK | | OS= | C | 176805 |
PEAK PLUMBING & HEATING, INC. | P= | C | 10/01/2012 | | HARRISJ | HARRISJ | | P= | C | 179777 |
PEAK PLUMBING & HEATING, INC. | PTO | C | 06/13/2012 | | HARRISJ | HARRISJ | | PTO | C | 177572 |
PEAK PLUMBING & HEATING, INC. | PB | C | 05/08/2012 | | HARRISJ | HARRISJ | | PB | C | 176954 |