THE COPESTONE COMPANY | BSP | R | 02/13/2009 | Temp CO expires...cms (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 162701 |
THE COPESTONE COMPANY | BSP | R | 02/02/2009 | rec'd balance report (Original code: 20, desc: Other, result: , inspector: JRH) | HARRISJ | HARRISJ | | BSP | R | 162461 |
THE COPESTONE COMPANY | B= | C | 02/02/2009 | all items correctedfor Temp CO...cms (Original code: 04, desc: Struc Final, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | B= | C | 16697 |
THE COPESTONE COMPANY | BSP | R | 01/14/2009 | RCVD LTR FROM COPESTONE AND COPY OF BOND REGARDING THE SEEDING OF THE LANDSCAPE. STATEING TO BE DONE BY APRIL 09 (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 162688 |
THE COPESTONE COMPANY | BSP | R | 01/12/2009 | RCVD LTR FROM FRED CLIFFORD REGARDING STRIPING OF PARKING LOT, STATING TO BE DONE MAY OF 09 (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 162689 |
THE COPESTONE COMPANY | BSP | R | 01/12/2009 | RCVD COMPACTION REPORT..CMS (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 162686 |
THE COPESTONE COMPANY | BSP | R | 01/12/2009 | RCVD TEST RESULTS FOR CONCRETE, BOND BEAMS, AND LTR FROM COPESTONE OF THE SETTING OF THE STEEL. CMS (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 162687 |
THE COPESTONE COMPANY | B= | R | 01/12/2009 | 1" clearence around b-vent wash bays/check water line hangers in bays/exposed belts in park storage loft/many places around building not sealed snow blowing in and water/tighten cross tensioners/cap air line in service bay/time frame for construction trailer and debris removalfire inspection scheduled for 1/9/09 midday...cmc (Original code: 04, desc: Struc Final, result: FAIL, inspector: JRH) | HARRISJ | HARRISJ | | B= | R | 16988 |
THE COPESTONE COMPANY | BSP | R | 01/09/2009 | Steve from Copestone says they passed fire dept inspection...cmc (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 162682 |
THE COPESTONE COMPANY | BSP | P | 12/29/2008 | HVAC for entire bldg...cmc (Original code: 20, desc: Other, result: Pend, inspector: JRH) | HARRISJ | HARRISJ | | BSP | P | 17159 |
THE COPESTONE COMPANY | BSP | R | 12/29/2008 | do complete walk thru on plumb/mech/hvac at struc final inspection (Original code: 20, desc: Other, result: , inspector: JRH) | HARRISJ | HARRISJ | | BSP | R | 160357 |
THE COPESTONE COMPANY | BSP | R | 12/24/2008 | I spoke with Larry from Copestone, plumbing and heating finals that are being called in are for the entire building. so please do these inspections as finals. cms (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 160379 |
WALL CONCEPTS, INC | BFR | C | 11/04/2008 | ljm 11/4/08--Framing interior walls for rooms: 113-115-125-126 and 224 2nd floor. This completes the framing.--akc (Original code: 03, desc: Struc Frame, result: pass, inspector: AKC) | CHAMBERLINA | CHAMBERLINA | | BFR | C | 18196 |
THE COPESTONE COMPANY | BSP | R | 10/24/2008 | WILL NEED METER READING AT FINAL INSPECTION....LJM (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 166675 |
THE COPESTONE COMPANY | BSP | R | 10/09/2008 | received CHANGE ORDER--and first two items were appproved on 10/09/08. the third item of deleting the one hour rated ceiling was approved by Vernon (engineer), on 10/21/08...MRB (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 166661 |
THE COPESTONE COMPANY | BIN | C | 08/13/2008 | for admin and locker rooms. cms (Original code: 29, desc: Energy Rough, result: pass, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BIN | C | 20501 |
THE COPESTONE COMPANY | BSP | C | 08/06/2008 | --ROOF DRAINS-- (Original code: 20, desc: Other, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BSP | C | 20677 |
WALL CONCEPTS, INC | BFR | P | 08/04/2008 | -- admin and lockers rooms -- INTERIOR FRAME OK, WILL NEED THIRD PARTY REPORTS FOR BOND BEAM AND WELDING, OK TO INSULATE AND DRYWALL, STILL NEED ABOVE CEILING ELEC AND HVAC AND PLUMB WATER TEST AND ROOF DRAINS--- (Original code: 03, desc: Struc Frame, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFR | P | 20751 |
WALL CONCEPTS, INC | BFR | R | 08/01/2008 | mens and womens ADA shower not framed per plan, remove insulation to check truss to bearing plates, submit third party inspecti0ons for bond beams,front admin area...cmc (Original code: 03, desc: Struc Frame, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFR | R | 20760 |
THE COPESTONE COMPANY | BSP | R | 05/23/2008 | ADAM CALLED AT 10/45 ON 5/23/08 TO CANCEL INSPECTION....LEFT MSG ON MARK'S CELL PHONE...LJMunderground piping called by Adam on voicemail....cmc (Original code: 20, desc: Other, result: , inspector: ) | | | | BSP | R | 157951 |
PEAK CONCRETE ENTERPRISES | BFN | C | 11/15/2007 | USED OIL STORAGE , CMS (Original code: 02, desc: Struc Foundation, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFN | C | 25892 |
THE COPESTONE COMPANY | BFT | C | 11/13/2007 | FOR OIL TANK FOOTING PAD EAST SIDE OF BUILDING CMS (Original code: 01, desc: Footing /Open Hole, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | C | 25964 |
THE COPESTONE COMPANY | BSP | C | 07/03/2007 | Partial Bond Beam (Original code: 20, desc: Other, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BSP | C | 30005 |
THE COPESTONE COMPANY | BSP | R | 06/29/2007 | canx via phone patial bond beam (Original code: 20, desc: Other, result: , inspector: MCL) | LANDSITTELM | LANDSITTELM | | BSP | R | 153876 |
PEAK CONCRETE ENTERPRISES | BFN | C | 06/28/2007 | OK - Front 4 Piers and retain wall (Original code: 02, desc: Struc Foundation, result: PASS, inspector: JVF) | FETROWJ | FETROWJ | | BFN | C | 30131 |
PEAK CONCRETE ENTERPRISES | BFN | C | 06/22/2007 | MARKED ON PLANS early morning please (Original code: 02, desc: Struc Foundation, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFN | C | 30298 |
PEAK CONCRETE ENTERPRISES | BFN | C | 06/18/2007 | OK - Left Side Partial - Marked on plans (Original code: 02, desc: Struc Foundation, result: PASS, inspector: JVF) | FETROWJ | FETROWJ | | BFN | C | 30483 |
PEAK CONCRETE ENTERPRISES | BFN | C | 06/15/2007 | requesting a. m. cms partial (Original code: 02, desc: Struc Foundation, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFN | C | 30532 |
THE COPESTONE COMPANY | BFT | C | 06/15/2007 | requesting a.m. cms, partial (Original code: 01, desc: Footing /Open Hole, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | C | 30531 |
THE COPESTONE COMPANY | BFT | C | 06/13/2007 | remaining pads east side on floater plans in yellow CMC (Original code: 01, desc: Footing /Open Hole, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | C | 30626 |
THE COPESTONE COMPANY | BFT | C | 06/12/2007 | need stamped from eng footer size CMS (Original code: 01, desc: Footing /Open Hole, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | C | 30644 |
THE COPESTONE COMPANY | BFT | R | 06/11/2007 | CLARIFY 2' FOOTER SHOWN ON PLAN AND DETAIL SHOWS 1' 4", PADS OK-- MARKED ON PLANS PARTIAL, REQUESTING P.M. CMS (Original code: 01, desc: Footing /Open Hole, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | R | 30697 |
THE COPESTONE COMPANY | BFT | P | 06/11/2007 | RECD FAX ON FOOTER SIZE, NEED STAMPED LETTER FROM ENG (Original code: 01, desc: Footing /Open Hole, result: PEND, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | P | 30710 |
PEAK CONCRETE ENTERPRISES | BFN | C | 06/07/2007 | EAST WALL FROM GRID 20 TO GRID 13 CMS (Original code: 02, desc: Struc Foundation, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | BFN | C | 30792 |
PEAK CONCRETE ENTERPRISES | BFN | C | 06/05/2007 | NORTH OFFICE WALLS PARTIAL, CMS (Original code: 02, desc: Struc Foundation, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFN | C | 30880 |
PEAK CONCRETE ENTERPRISES | BFN | C | 06/04/2007 | PARTIAL (Original code: 02, desc: Struc Foundation, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFN | C | 30916 |
THE COPESTONE COMPANY | BFT | C | 06/04/2007 | DETAIL SHOWS 24" NOT 20" FOOTING PARTIAL (Original code: 01, desc: Footing /Open Hole, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | C | 30915 |
THE COPESTONE COMPANY | BFT | P | 05/31/2007 | NORTH FOOTINGS SEE FLOATER PLANS IN YELLOW partial (Original code: 01, desc: Footing /Open Hole, result: PART, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | P | 30976 |
PEAK CONCRETE ENTERPRISES | BFN | P | 05/25/2007 | REQUESTING PM , PARTIAL FOUNATION CMS. (Original code: 02, desc: Struc Foundation, result: part, inspector: JRH) | HARRISJ | HARRISJ | | BFN | P | 31113 |
THE COPESTONE COMPANY | BFT | P | 05/22/2007 | IN YELLOW, PADS EAST & WEST SECTION LINES 12-20 ANOTHER PARTIAL. CMS (Original code: 01, desc: Footing, result: PART, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | P | 31197 |
THE COPESTONE COMPANY | BFT | P | 05/17/2007 | yellow hi lighter on floater plans PARTIAL FOOTER...CMC (Original code: 01, desc: Footing /Open Hole, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | BFT | P | 31345 |
MORTON ELECTRIC INC | E= | C | 12/30/2008 | Replace defective frogeye, rkd. (Original code: 08, desc: Elec Final, result: pass, inspector: RKD) | DRUMR | DRUMR | | E= | C | 17145 |
MORTON ELECTRIC INC | E= | C | 12/23/2008 | PARTIAL FOR ASPECTS WHICH APPLY TO PLUMBING & HEATING...REQUEST AM....CMC This inspection was to verify the fact that mechanical equiptment and plumbing equiptment were correctly installed . By passing this inspection it is now OK to request heat and plumbing finals, rkd (Original code: 08, desc: Elec Final, result: pass, inspector: RKD) | DRUMR | DRUMR | | E= | C | 17184 |
MORTON ELECTRIC INC | ER | C | 12/17/2008 | re-inspect for wash bay lighting support, rkd (Original code: 07, desc: Elec Rough, result: pass, inspector: RKD) | DRUMR | DRUMR | | ER | C | 17285 |
MORTON ELECTRIC INC | ER | R | 12/10/2008 | See notes from above, rkd No fixture supports installed, rkd (Original code: 07, desc: Elec Rough, result: fail, inspector: RKD) | DRUMR | DRUMR | | ER | R | 17410 |
MORTON ELECTRIC INC | E= | C | 11/21/2008 | fuel monitoring station....request PM...cmc For fuel pump service only, rkd, released perm meter 11-21-2008, rkd (Original code: 08, desc: Elec Final, result: pass, inspector: RKD) | DRUMR | DRUMR | | E= | C | 17740 |
MORTON ELECTRIC INC | E= | R | 11/20/2008 | FUEL MONITORING STATION Nothing changed with depth installed non-fused disconnect at meter , rkd (Original code: 08, desc: Elec Final, result: fail, inspector: RKD) | DRUMR | DRUMR | | E= | R | 17812 |
MORTON ELECTRIC INC | ER | R | 11/14/2008 | inspection for 100amp fuel monitoring station....see scope of work in file...cmc Charla claims that Territory Elect. didn't do this, rkd (Original code: 07, desc: Elec Rough, result: fail, inspector: RKD) | DRUMR | DRUMR | | ER | R | 17950 |
MORTON ELECTRIC INC | ER | C | 10/31/2008 | ROOMS 125, 126, 112, 113, 116, this will complete rough. ( rms are 2 offices at parts storage, and storage areas by wash bay) This will complete the rough for this job, rkd (Original code: 07, desc: Elec Rough, result: pass, inspector: RKD) | DRUMR | DRUMR | | ER | C | 18302 |
MORTON ELECTRIC INC | ER | C | 09/05/2008 | above gride ceiling in offfice, cms ( building gets locks up at 3:00 pm) (Original code: 07, desc: Elec Rough, result: pass, inspector: RKD) | DRUMR | DRUMR | | ER | C | 19872 |
MORTON ELECTRIC INC | ER | C | 08/15/2008 | ABOVE HARD CEILING (Original code: 07, desc: Elec Rough, result: pass, inspector: RKD) | DRUMR | DRUMR | | ER | C | 20420 |
MORTON ELECTRIC INC | ER | C | 07/31/2008 | front walls of bldg....cmc This was for concieled wall work only in the front of the building the ballance of this project will be surface mount, rkd (Original code: 07, desc: Elec Rough, result: pass, inspector: RKD) | DRUMR | DRUMR | | ER | C | 20796 |
MORTON ELECTRIC INC | ER | C | 07/24/2008 | conduit under slab....request PM if possible...cmc Interior under slab inspection, for center portion of building only, rkd (Original code: 07, desc: Elec Rough, result: pass, inspector: RKD) | DRUMR | DRUMR | | ER | C | 20959 |
MORTON ELECTRIC INC | EUG | C | 05/09/2008 | for new service for fuel station CMS (Original code: 31, desc: Electrical Trench, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | EUG | C | 22668 |
MORTON ELECTRIC INC | EUG | R | 05/09/2008 | only one trench to look at (Original code: 31, desc: Electrical Trench, result: , inspector: JRH) | HARRISJ | HARRISJ | | EUG | R | 157994 |
MORTON ELECTRIC INC | ES | C | 12/26/2007 | Released perm meter 12-26-2007, rkid. (Original code: 06, desc: Elec Permanent, result: pass, inspector: RKD) | DRUMR | DRUMR | | ES | C | 25074 |
MORTON ELECTRIC INC | ES | R | 12/11/2007 | cms, left trim off will put back on after pass no underground inspection, un-marked wiresin neutral bar, rkd (Original code: 06, desc: Elec Permanent, result: fail, inspector: RKD) | DRUMR | DRUMR | | ES | R | 25300 |
MORTON ELECTRIC INC | EUG | C | 07/25/2007 | AS EARLY AS POSSIBLE PLEASE, THIS IS UNDER SLAB CONDUIT INSPECTION. Need to correct fitting on eufer , used mechanical TA lug, I don't think that it's listed for use in concrete, rkd (Original code: 31, desc: Electrical Trench, result: pass, inspector: RKD) | DRUMR | DRUMR | | EUG | C | 29318 |
NIELSEN MECHANICAL CONTRACTORS | H= | C | 01/12/2009 | (Original code: 14, desc: Heat Final, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | H= | C | 16992 |
NIELSEN MECHANICAL CONTRACTORS | H= | P | 12/29/2008 | cms (Original code: 14, desc: Heat Final, result: Pend, inspector: JRH) | HARRISJ | HARRISJ | | H= | P | 17158 |
NIELSEN MECHANICAL CONTRACTORS | H= | R | 12/12/2008 | --need elec final to pass before other final called in--cmc (Original code: 14, desc: Heat Final, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | H= | R | 17342 |
PROFESSIONAL PIPING, LLC. | HI | C | 12/03/2008 | --THIS COMPLETES GAS LINE--south side of bldg...cmc (Original code: 12, desc: Gas Line Bldg, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | HI | C | 17537 |
PROFESSIONAL PIPING, LLC. | HI | P | 10/10/2008 | --from meter to north admin and to section 17, 2" from 2.5" welded, med pressure--10/09/08--grid line 17 to the front of building..This is from a change order received 10/09/08 and approved on 10/10/08...MRB (Original code: 12, desc: Gas Line Bldg, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | HI | P | 18845 |
PROFESSIONAL PIPING, LLC. | HI | P | 10/08/2008 | -- 60 # test for part ok need chg order for med pressure gas approved--cms (Original code: 12, desc: Gas Line Bldg, result: pend, inspector: MCL) | LANDSITTELM | LANDSITTELM | | HI | P | 18910 |
NIELSEN MECHANICAL CONTRACTORS | HV | C | 09/10/2008 | --office area, vents OK, NEED TO VTR PVC AND COVER FOAM INSULATION WITH BATTS FIBERGLASS-- (Original code: 16, desc: Vents/Ducts, result: pass, inspector: MCL) | LANDSITTELM | LANDSITTELM | | HV | C | 19768 |
NIELSEN MECHANICAL CONTRACTORS | HV | C | 08/15/2008 | --above ceiling RI front admin and lockers rooms, ok to insulate-- (Original code: 16, desc: Vents/Ducts, result: pass, inspector: JRH) | HARRISJ | HARRISJ | | HV | C | 20423 |
NIELSEN MECHANICAL CONTRACTORS | HV | R | 08/13/2008 | --NOT SIZED PER PLAN-- above ceiling in office (Original code: 16, desc: Vents/Ducts, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | HV | R | 20500 |
PROFESSIONAL PIPING, LLC. | P= | C | 01/12/2009 | (Original code: 11, desc: Plumb Final, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | P= | C | 16991 |
PROFESSIONAL PIPING, LLC. | P= | P | 12/29/2008 | cms (Original code: 11, desc: Plumb Final, result: Pend, inspector: JRH) | HARRISJ | HARRISJ | | P= | P | 17157 |
PROFESSIONAL PIPING, LLC. | P= | | 12/23/2008 | no plumbers on site did not have a clue what they wanted me to inspect CMC (Original code: 11, desc: Plumb Final, result: ????, inspector: JRH) | HARRISJ | HARRISJ | | P= | | 17185 |
PROFESSIONAL PIPING, LLC. | PTO | C | 11/10/2008 | --WALLS ok NEED TO TIE IN WATER--for central bathroom...cmc (Original code: 10, desc: Plumb T/O & Supp, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PTO | C | 18061 |
PROFESSIONAL PIPING, LLC. | PTO | C | 08/15/2008 | (Original code: 10, desc: Plumb T/O & Supp, result: PASS, inspector: JRH) | HARRISJ | HARRISJ | | PTO | C | 20405 |
PROFESSIONAL PIPING, LLC. | PTO | P | 08/01/2008 | --dwv OK need water and roof drains above ceiling--bathroom walls....cmc (Original code: 10, desc: Plumb T/O & Supp, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PTO | P | 20756 |
PROFESSIONAL PIPING, LLC. | PB | C | 07/16/2008 | -- EYE WASH AND FD AND WATER ENTRY MIDDLE OF BUILDING, THIS COMPLETES BASE PLUMB---CMS (Original code: 09, desc: Plumb Base, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | C | 21169 |
PROFESSIONAL PIPING, LLC. | PB | P | 07/11/2008 | --bathroom in middle of building-- (Original code: 09, desc: Plumb Base, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 21266 |
PROFESSIONAL PIPING, LLC. | PB | P | 06/26/2008 | --THIS COMPLETES THE TRENCH DRAINS, STIIL NEED A LITTLE MORE BASE ON SS--- (Original code: 09, desc: Plumb Base, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 21607 |
PROFESSIONAL PIPING, LLC. | PB | R | 06/25/2008 | -- backgrade to flat by test tee---south side of building, cms (Original code: 09, desc: Plumb Base, result: FAIL, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | R | 21649 |
PROFESSIONAL PIPING, LLC. | PB | P | 06/18/2008 | --trench drains to south 104A-- (Original code: 09, desc: Plumb Base, result: PART, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 21821 |
PROFESSIONAL PIPING, LLC. | PB | P | 06/04/2008 | wash bay area, trench drains and SS, NOTE MOST OF THE BASE WILL BE REDONE DUE TO MUD JACKING. (Original code: 09, desc: Plumb Base, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 22177 |
PROFESSIONAL PIPING, LLC. | PB | P | 05/27/2008 | locker room retest OK, and 3" south to CMU wall by motor vehicle bay (Original code: 09, desc: Plumb Base, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 22359 |
PROFESSIONAL PIPING, LLC. | PB | P | 05/22/2008 | 3" from locker rm to south LOCKER ROOM...CMC (Original code: 09, desc: Plumb Base, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 22433 |
PROFESSIONAL PIPING, LLC. | PB | C | 05/16/2008 | WILL NEED TO RETEST BATHROOM GROUP, TOO MUCH DAMAGE--break room only, cms (Original code: 09, desc: Plumb Base, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | C | 22565 |
PROFESSIONAL PIPING, LLC. | PB | P | 07/17/2007 | 4" out to sewer NORTHEND OF BUILDING, WHERE OFFICES ARE. CMS (Original code: 09, desc: Plumb Base, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 29550 |
PROFESSIONAL PIPING, LLC. | PB | P | 07/13/2007 | NORTH END, MESS, DID NOT SAY WHAT FOR CMS (Original code: 09, desc: Plumb Base, result: part, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | P | 29670 |
PROFESSIONAL PIPING, LLC. | PB | C | 07/06/2007 | PARTIAL FOR BASE PLUMBING & SANDTRAPS...CMC (Original code: 09, desc: Plumb Base, result: PASS, inspector: MCL) | LANDSITTELM | LANDSITTELM | | PB | C | 29872 |